1.1These test methods cover the testing of heat-shrinkable tubing used for electrical insulation. Materials used include poly(vinyl chloride), polyolefins, fluorocarbon polymers, silicone rubber, and other plastic or elastomeric compounds.
1.2The procedures appear in the following sections:
| Procedure | Sections | ASTM Method Reference |
| Adhesive Peel Strength | 98 - 104 | |
| Brittleness Temperature | 40 | D746 |
| Color | 55 and 56 | D1535 |
| Color Stability | 57 - 62 | D1535 |
| Conditioning | 7 | D618 |
| Copper Stability | 93 | |
| Corrosion Testing | 89 - 95 | |
| Dielectric Breakdown | 20 - 25 | D149 |
| Dimensions | 8 - 13 | D876 |
| Flammability | 68 - 72 | D876 |
| Fluid Resistance | 63 - 67 | |
| Fungus Resistance | 104 - 108 | |
| Heat Resistance | 49 - 54 | |
| Heat Shock | 26 - 30 | |
| Low-Temperature Properties | 36 - 43 | |
| Restricted Shrinkage | 14 - 19 | |
| Selection of Test Specimens | 6 | |
| Secant Modulus | 81 - 84 | D882 |
| Storage Life | 31 - 35 | |
| Specific Gravity | 73 and 74 | D792 |
| Stress Modulus | 85 - 88 | D412 |
| Tensile Strength and Ultimate Elongation | 44 - 48 | D412 |
| Thermal Endurance | 96 and 97 | |
| Volume Resistivity | 75 - 78 | D257 |
| Water Absorption | 79 and 80 | D570 |
| Melting Point | 104 - 108 | D3418 |
1.3This is a fire-test-response standard.
1.4The values stated in inch-pound units are to be regarded as standard, except for temperature, which shall be expressed in degrees Celsius. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Sections 5 and 68.2.