ASTM C1517-09

Standard Test Method for Determination of Metallic Impurities in Uranium Metal or Compounds by DC-Arc Emission Spectroscopy

ASTM International , 06/01/2009

$26.00 $52.00

1.1 This test method describes the steps necessary for the preparation and determination of impurity metals in uranium metal and uranium compounds by DC arc emission spectroscopy.

1.2 The method is valid for those materials that can be dissolved in acid and/or converted to an oxide in a muffle furnace (see Practice C 1347).

1.3 This method uses the carrier distillation technique to selectively carry the impurities into the arc, leaving the uranium oxide in the electrode. If it is necessary to determine the carrier metal(usually a silver or strontium, or gallium compound) as an impurity, another technique must be chosen for that element.

1.4 Units - The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.

1.5 This standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Information

Published: 06/01/2009
Pages: 4
File Size: 1 file , 85 KB
Language: English
Note: This product is unavailable in Russia, Ukraine, Belarus
ASTM C1517-24
ASTM C1517-24

$35.00

ASTM C1517-16
ASTM C1517-16

$42.00

ASTM C1517-09
ASTM C1517-09

$26.00

Related Documents

ASTM D5823-19
ASTM D5823-19

$33.00

ASTM D5917-15
ASTM D5917-15

$29.00

ASTM B758-00(2011)
ASTM F917-91(2008)e1