These clamps are intended for use as follows:
Temperature Range: -65 degrees F to +275 degrees F (For higher
temperature rated clamps, see NASM85449/3 Clamps).
Systems:
1. All aromatic fuel system applications requiring a high degree of
cushion exposure to system fluid.
2. All fluid and electrical systems on aircraft and aerospace vehicles
using petroleum based hydraulic systems.
3. In electrical systems for support of wire bundles provided multiple
wire bundles are wrapped or contained in conduits or other wire
protection tubing.
4. In systems with high vibration areas such as near pumps, motors,
etc. It is to be noted that NASM85449 requires vibration tests only
up to the -24 size clamp. Larger clamps used in high vibration areas
should be subjected to additional testing.
The complete requirements for acquiring the clamps described herein shall consist of this specification sheet and the latest issue of NASM85449.