TIA TIA-455-186

FOTP-186 Gauge Retention Force Measurement for Fiber Optic Components

Telecommunications Industry Association , 07/01/1991

$35.00 $69.00
ANSI APPROVAL WITHDRAWN MARCH 2004

INTRODUCTION

Intent

This procedure is used to measure the retention characteristics of the resilient member of a fiber optic component (most commonly a connector). It is specifically intended for use when it is impracticable to define acceptance/rejection criteria for resilient members by the use of size dimensions.

Description

The method is applicable to either male or female resilient members. For the case of a male member, a ring gauge is forced over the member and the minimum frictional force to pull it off is assessed by its ability to pick up a weight. The procedure is identical for a female resilient member except that a gauge pin is substituted for the ring gauge.

Alternative Procedures

This test procedure is an alternative to the measurement procedure, titled Gauge Retention Force, of IEC 874-1, Third Edition.

Product Information

Published: 07/01/1991
Pages: 12
File Size: 1 file , 230 KB
Language: English