SAE J3277/1_202501 PDF
This recommended practice (RP) establishes nondestructive in-line production test methods for evaluating the water leak tightness of propulsion battery packs. It aims to achieve results equivalent to the IEC 60529 standard’s IPX7 level using the Selected Equivalent Channel (EC) method defined in SAE J3277. This RP provides guidance for system setup, tooling design, validation, and leak test procedures. It acknowledges the limitations of certain battery pack designs and recommends appropriate air or tracer gas leak tightness technologies.
Specifically, this RP covers nondestructive end-of-line leak testing for: