IEEE 1708-2014

IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices

IEEE , 08/26/2014

$41.00 $81.00

IEEE 1708-2014 PDF

The intent of this standard is to establish objective performance evaluation of wearable, cuffless blood pressure (BP) measuring devices. The standard is independent of the form of the device or the vehicle to which the device is attached or in which it is embedded. The standard is applicable to all types of wearable BP measurement devices that have different modes of operation (e.g., to measure short-term, long-term, snapshot, continuous, beat(s)-to-beat(s) BP, or BP variability). This standard is, however, limited to evaluation of devices that do not use a cuff during measurement and does not cover evaluation of all sphygmomanometers that are used with an occluding or inflatable cuff for the indirect determination of BP on the upper arm or wrist. There is currently no defined, independent standard for wearable cuffless BP measurement devices, which have drawn growing interest in recent years. Existing standards for evaluating sphygmomanometers are intended only for devices that are used with an occluding cuff and, therefore, do not cover all aspects needed for the emerging wearable devices. This standard provides guidelines for manufacturers to qualify and validate their products, potential purchasers or users to evaluate and select prospective products, and health care professionals to understand the manufacturing practices on wearable BP devices. New IEEE Standard - Active. IEEE Std 1708 establishes a normative definition of wearable cuffless blood pressure (BP) measuring devices and the objective performance evaluation of this kind of device. The standard is independent of the form of the device or the vehicle to which the device is attached or in which it is embedded. The standard is applicable to all types of wearable BP measurement devices including epidermal and unobtrusive BP devices that have different modes of operation (e.g., to measure short-term, long-term, snapshot, continuous, beat(s)-to-beat(s) BP, or BP variability). This standard is, however, limited to evaluation of devices that do not use a cuff during measurement and do not cover evaluation of all sphygmomanometers that are used with an occluding or inflatable cuff for the indirect determination of BP on the upper arm or wrist. This standard provides guidelines for manufacturers to qualify and validate their products, potential purchasers or users to evaluate and select prospective products, and health care professionals to understand the manufacturing practices on wearable BP devices.

Product Information

Published: 08/26/2014
Pages: 32
ISBN: 9780738192147, 9781504416566, 9780738192130
File Size: 1 file , 2.6 MB
Language: English
Note: This product is unavailable in Russia, Ukraine, Belarus

Related Documents

IEEE C2-2023
IEEE C2-2023

$107.00

IEEE 1364.1-2002
IEEE C37.121-2020
IEEE 802.5t-2000